Chapter 8 - Maintenance
8.8.4.5. CASE 5
When initialisation ends up properly, display is:
Note:
From this step, left point is flashing fast.
8.8.4.6. CASE 6
•RSI(1) case: Either J117 on RSI or J1303, 3-4 at the back of CS8C are defective (bad
contacts) (the regeneration thermoswitch is not implemented).
•RSI2 case: This input does not exist.
8.8.4.7. CASE 7
RSI is powered from ARPS 24V1 output.
If 24V1 led on ARPS is Off:
See chapter 8.6, page 176.
If 24V1 led on ARPS is On:
Check wiring between ARPS J1102 and RSI J104.
Figure 8.49
If wiring is OK, change RSI.
- (i) Waiting for the power supply to be switched on
Problem:
(0) Regeneration thermoswitch: Contact J1303, 3-4 open
Solution:
Problem:
(1) RSI board power supply problem: J104, 1-6 or internal power
supplies
Solution:
?
?
RSI
ARPS
J1102-4
J1102-12
J104-1
J104-6
24V1
0V1
24V1
0V1