Robotics Sportster Flash x2 Instrukcja Użytkownika Strona 9

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 8
Version 1.0 - June 19, 1997 1997 U.S. Robotics - All Rights Reserved
3. Ensure that the S-registers are set properly.
As with the clients, there are a number of S-Registers that control how x2 works and
that can disable all or some of the functionality. Those registers and the recommended
values for full x2 functionality are shown in the following screen.
B0 C1 E1 F1 Q0 V1 X1
BAUD=19200 PARITY=N WORDLEN=8 DTE=GATEWAY NAC
DIAL=TONE ON HOOK TIMER LINE=ISDN PRI
&A3 &B1 &C1 &D2 &G0 &H1 &I0 &K1 &L0 &M4 &N0
&P0 &R1 &S0 &T4 &U0 &X0 &Y1 %N6
S00=001 S01=000 S02=043 S03=013 S04=010 S05=008 S06=002 S07=060
S08=002 S09=006 S10=014 S11=070 S12=050 S13=000 S14=000 S15=000
S16=000 S17=000 S18=000 S19=000 S20=000 S21=010 S22=017 S23=019
S24=150 S25=005 S26=001 S27=000 S28=008 S29=020 S30=000 S31=000
S32=009 S33=000 S34=000 S35=000 S36=000 S37=000 S38=000 S39=011
S40=000 S41=000 S42=126 S43=200 S44=015 S45=000 S46=255 S47=032
S48=000 S49=016 S50=100 S51=000 S52=005 S53=000 S54=064 S55=000
S56=000 S57=000 S58=000 S59=000 S60=000 S61=000 S62=000 S63=000
S64=000 S65=000 S66=000 S67=000 S68=000 S69=002 S70=000 S71=001
S72=001 S73=001 S74=000 S75=000 S76=000 S77=000 S78=000
LAST DIALED #: T9825092
LAST DNIS #: 1111 LAST ANI #: 8471111111
OK
IMPORTANT:
Make sure to “Restore the Modems from Factory Defaults” after upgrading to
5.0.7/5.1.7 to ensure that new registers have valid settings. These settings should be
made to all modems in the chassis (or pools that are receiving x2 calls, if pooling
functionality is configured).
For Quad Modem code version 5.0.7 or 5.1.7, make sure the setting for S10 is 14. For
versions 5.6 and 5.7, use S10=7.
4. Ensure that the lines are “trunk-side.”
In most cases, you can assume that there are no analog-to-digital conversions in the
network (behind your CO switch), but if all else fails, that should be investigated.
n Dial into an x2 host from a terminal program. Set S14=0 prior to dialing to prevent
a disconnect on escape. At the “login” prompt (or whatever is displayed after
connect) type +++ to get to the modem’s command prompt. While still online, enter
(and capture the results if possible): ATI4I6I7I11Y11